MARKETS
iCorrLog
Facts:
Maintenance Measurements
DCVG / CIPS (Close Interval Potential Survey)
Soil resistance measurement
Micro volt measurement
Stray current or AC-interference measurements
Logging
synchronous clocking of Systems or coupons
...CP engineers and technicians carry a multitude of measurement devices with specific capabilities to carry out these surveys. Often, the drawers and tool boxes in the vehicle are filled with equipment, such instruments incur a definite cost to the company and demand further investments.
Technical Data:
- 4 Channel CP multimeter (always AC+DC in parallel) with FFT-Analysis
Channel 1-3 switchable ±150V, ±15V, ±5V,
impedance 30MOhms
Channel 4 switchable ±1,5V, ±300mV, ±15mV
impedance 440kOhms
(optional 1500mA | impedance < 0,5Ohms) - 2kHz 8-track datalogger
- Routine maintenance measurements
- Stray current measurements (DC / AC)
- Intensive- (DCVG / CIPS) Measurements
- mobile, free parameterizable and GPS clocking relay
- Micro voltmeter
- AC soil resistance measurements
- Barrier-free operation also via smartphone or tablet app
- 16GB / 32GB memory
SIMILAR PRODUCTS